0 товаров в запросе на предложение
"Reliable and solid company I work with for years. They always deliver what they promise. Clear agreements, good cash for our surplus equipment and rapid collection."
Biopharma company located in Brussels, Belgium
"Reliable and solid company I work with for years. They always deliver what they promise. Clear agreements, good cash for our surplus equipment and rapid collection."
Biopharma company located in Brussels, Belgium
0 товаров в запросе на предложение
The tank is equipped with a pressure gauge, a temperature sensor, level switches, and manually or pneumatically operated valves, including safety devices (rupture disc).
The tank is installed on load cells.
System connections: product inlet and outlet; nitrogen or process air supply; vent line; CIP connection; electrical power supply; control system interface; cooling water inlet and outlet.
Internal surface finish: electropolished, Ra < 0.8 µm.
The unit is designed and manufactured in accordance with GMP guidelines and is fully cleanable (no dead legs or inaccessible areas).
The system is configured as a standalone unit with SIMATIC data exchange (S7–S7 communication).
Design: ATEX Zone 2 (internal and external), CE compliant.
The vessels have successfully passed FAT and are available for purchase and shipment.